Single Point Load Cell SPA

Single Point
Single Point Load Cell SPA
DETAILS

SPA is single point low profile load cell, designed for platform scales, belt scales and check weighing applications. Made from high quality anodized aluminum, SPA is the good choice for simply-constructed applications.

Applications

  • Platform scales
  • Belt scales
  • Check weighing applications

Main specifications

Rated capacities (Emax)3,5,6,10,15,20,25,30,35,40,45,50,60,100,200kgTemperature range, compensated-10°C ≈ +40°C
Sensitivity2.0±0.02mV/V Temperature range, operating-20°C ≈ +50°C
Accuracy clessC3,C5,C6Maximum safe overload150% Emax
Creep error (30min)± 166ppmUltimate overload300% Emax
Zero balance± 3%EmaxExcitation, recommended10V DC
TC ZERO Excitation, maximum15V DC
TC SPAN+20°C ≈ +40°C, ± 17.5ppm/°CProtection classAluminium
 -10°C ≈ +20°C, ± 11.67ppm/°CConstruction0.5m@ Ø 5mm
Input resistance404 ± 10ΩCable25N-m
Output resistance350 ± 3ΩInstallation torque recommended 
Insulation resistance≥ 2000MΩ (50V DC)  
Max. platform size